com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. yello3d. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. g. Other possible causes are a bad stepper motor or cable. Click to Enlarge. @Phaedrux said in Extruder motor not working. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. . . For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. Now with Marilin 2. 0 ; set drive mapping M350 X16 Y16 Z16 E16 I1 ; configure microstepping with interpolationThermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. Once satisfied the extruder drive is working, re-enable cold extrusion prevention using the following command: M302 P0 Reset the Active temperature for Heater 1 back to 190C. The Matrice 30 series integrates multiple high-performance sensors into a lightweight and portable body. x) or M557 P1 S0 (FW >3. To test for this, with the power off swap the E0 connector on the Duet with another one e. G92 E0 ;zero the extruded length again. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. From nozzles to swing pipes, Rain Bird offers a broad range of sprinkler parts and accessories to meet your irrigation needs. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. Your config files updated for bugfix Configuration. Extrusion Control in DWC unavailable, even after M302 P1. ; pre 3. In order to report the current status, run. Tried setting up the extruder on drive 4 then on drive 3. +Z should move the bed down. 1 Reply Last reply Reply Quote 0. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". 8Hz when using P4. Users of single-extruder machines often put a T0 command at the end of config. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. Connector for the extruder is plugged into second connection (i. This is the case even with M302 P1 at the bottom of the config. Hello, I am building a clay printer and everything is working fine so far (with your help). The 3D models contain files for a mechanical gripper that attaches to the print head of the printer and can move chess pieces around. Last edit at 01/11/2023 01:58AM by Dust. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. Disable any mesh bed leveling procedures in. Page 28 2. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. g-code M302 P1; commonly used with syringe extrusion-based heads: Extruder temperature: g-code M104 S < Temperature >; 20 − 250 °C: Bed temperature: g-code M190 S < Temperature >; 20 − 150 °C: Extruder calibration: Firmware default: Uses the calibration defined in the 3D printer firmware: Steps per millimeter for the extruder a:. Re: Extrude without a Hotend May 04, 2017 11:25PM. To test for this, with the power off swap the E0 connector on the Duet with another one e. M109 S235 T0 ; set hotend temperature and wait. . @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. There is a web tool for this here which can make this easier for configuring another printer. @jfavre said in Extruder motor not working. I am at a loss for next step. Set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off, Minimum fan value 0. 0. Viko. Command "M302 P1" works properly. 1 Reply Last reply Reply Quote 0. Re: Extrude without a Hotend May 04, 2017 11:25PM. If that's not the case, we need to change the direction of rotation. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. The printer goes in the path determined by the slicer but the syringe does not extrude the gel. I have preheated the nozzle to 160 and also tried to issue a M302 P1 but that does not help either. If you are using the web interface, go to the Gcode. 36°C/sec measured -0. g file and M302 reporting that cold extrusion is. I have a duex5 attached to a Duet Wifi with firmware 2. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. Our innovative life science, applied science, and clinical products are now found under the Applied Biosystems™, Invitrogen™, Gibco™, Ion Torrent™, and Molecular Probes™ brands. 168. yello3d. 0 goes forwards M584 X0. G1 E15 F500 ; load filament insi de the gears. In that case we must change the motor direction once again M569 P3 S1 ; physical drive 3 goes forwards Change S1 to S0@gixxerfast said in BL Touch not working: Which version of RRF are you using, ver 2? I can't see that you've mentioned it. I cannot get the extruder controls to show up in the web interface - it is greyed out. There is no minimum steps/mm set in the firmware. M302 P1 will disable the temperature check that disables the extruder when the nozzle is cold. I would be very gratefull for any help. M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1. And now even Col Extrusion M302 P1 is generating errors. On Duet 3 if I send "M302P1" from the GCode console it returns "Error: Bad command". g (typically the Tools section) but write down the configured heater, fan, and extruder numbers mapped to. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Hello. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. Click to Enlarge. Send T0 in the gcode console and check the buttons again. G4 S1 ; wait for one second. CryptoM21 P1 M22 Release SD card M23 [filename. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. M302 P0 ; disable cold extrusion M291 P"Filament autoload complete!" S0 T3 ; display message . Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:Hey all, my melzi finally died. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. Crypto‘M302 P1 ; disable cold extrusion checking’ 2. g. the 0, 1,2 drivers still work fine. My printer doesn't have extrusion but when I push it manually it extrudes just fine. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. M302 P0 S170. after turning off cold hotend detection with M302 P1. Re: How can I move E steppers? January 11, 2023 02:36AMFailure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. She said the item was unless to me meatbagI have a duex5 attached to a Duet Wifi with firmware 2. Product Line: Ford Performance Parts Rear Main Seals. Only users with topic management privileges can see it. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. Allow cold extrusion: M302 P1; Relative mode: M83; Extrude 30 cm at 500mm/min: G1 E300 F500; Check if the length is 30 cm; If not OK: Fans are 12V, so I did wire in the 12V to the V_FAN. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysG-code for the 4th axis of the tangential knife after a slight modification {ASCI "conversion " (" to ";" and "A" to "E") allows you to run the code in the Marlin software. droftarts administrators @flyscha last edited by . The macro folder can divided into sub directories to more easily organise your macros by type. gpIn[0]. 23". @patel said in how to change homing sequence: M3D promega There's a full guide to this on M3D's Promega support pages. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. Fix the actual problem, which is that Marlin has a safety feature to protect the extruder and hotend by preventing extrusion when the temperature is below a certain margin. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. the X motor. I read up on the on "Connecting endstop switches - What might go wrong" and then I corrected the wiring and all is good with that. Ralms @fcwilt 8 Aug 2020, 08:57. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. send T0), and enable cold extrusion with M302 P1. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. @DjDemonD:. M302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. 0C. Thermostatic control is turned off. 0. M302 P1 disables the cold extrude safety. 3 ; Filter fan. M569 P1. 9Hz when using S4 or P4 Q50 resp. This topic has been deleted. Many thanks! ;FLAVOR:Marlin ;TIME:40 ;Filament used: 0. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?M302 P1; Allow cold extrude : T0; select tool 0: G10 P0 S180; heat tool 0 to 180 and wait: M116 P0: G10 P0 S120; cool tool 0 to 120 and wait: M116 P0: G1 E-20 F300; retract 20mm at 5mm/sec; change the following E values to suit your Bowden Tube length : G1 E-50 F600; retract another 50mm at 10mm/sec: G1 E-200 F3000; retract another 150mm at. I have a duex5 attached to a Duet Wifi with firmware 2. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x Digital. 06. gco] Select SD file M23 filename. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x. 0. This will hopefully make it a bit easier for me to. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. @Phaedrux said in Extruder motor not working. . Then reduce the distance, and stop just before the filament disappears into the hot end. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. 4 card. Large delta printer [miscsolutions. x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Hi I am building a machine that is not a 3D printer but as I have liked a lot Duets for years now I decided to use one as a controller in this project too. This topic has been deleted. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. droftarts administrators @flyscha last edited by . g . wordpress. The extruder motor turns but it won't really push the filaments to get extruded. 2 Firmware:3. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. Saying G0/G1 insufficient homing What could be the reasonThis topic has been deleted. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. 7mm, the output contact is engaged @ about 0. 13. This topic has been deleted. Hi all, Can anyone help using DC42 firmware I cannot get the extruder to cold extrude even when using the M302 P[1/0] to enable or disable the prevention. Ok i did the test you asked and did the commands thru the gcode console and with tool 0 on drive 0 selected when i give the G1 E20 F5 command i get a slight twitch on the motor shaft but the shaft spins freely with little to no resistance on the shaft i switched the motor cable to the drive 1 and set my config_g to use tool 0 drive one and with tool 0. 0. Let me explain better: I need to set the T0 value to 170/25 degrees as dummy to run the right Titan to verify the right amount of filament that extr. The SMuFF is supposed to beep for 1 second. trigger3. To test for this, with the power off swap the E0 connector on the Duet with another one e. oracledude 5 Dec 2021, 21:47. . retraction temperature 90. 3 ; Filter. Last edit at 01/11/2023 01:58AM by Dust. 042". Pix4d often makes vertical surfaces to 45 deg where they meet the ground. 1 OS hope it might work on it. Unmount the SD card and insert it into the Duet 2 Maestro board and power on. Support and Discussion forum for Duet3D Hardware, Firmware, Software, plugins and wider 3d printing/CNC discussion. 3 (3. When I try to run the extruder (for example G1 E1) I make sure to allow cold extrusion (M302 P1). (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Usage. microswitch) endstop. 2. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops. Send M302 P1 to allow cold extrusion. The prototype was outsourced to Oshpark. 8. g to make the process as painless as possible. Reply Quote. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 00°C/sec. 1 active and standby temperatures to 0C. M302 P1 ; enable cold extrusion. Featured product areas:As well as selecting the tool with e. g on the SD card (you can do this in the web interface). M302 P1 ;allow cold extrusion T0 G1 E1000 F3600 ;new step/mm = old*1000/Measured ;example 1024 measured with old steps = 310 -> new = 310*1000/1024 = 302. And now even Col Extrusion M302 P1 is generating errors. , appendicitis, cholecystitis,) Choice of first-line test will depend on likely origin of pain and suspected clinical diagnosis, for example: If acute. . The macro folder can divided into sub directories to more easily organise your macros by type. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Life Technologies was acquired by Thermo Fisher Scientific in January, 2014. retraction temperature 90. . May 04, 2017 11:25PM. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Probably I need to enable cold extrusion, but when I tried to add the M302 P1 or M302 S0, it does not work. Thanks for the reply. 4. I need to print some PCL filament, which melts optimally at 100 C°. 22. M302 works fine in a starting script or sent via console. G-Codes¶. The prototype was outsourced to Oshpark. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Don't forget to send M302 P0 later to restore normal safety. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. For firmware versions 1. Reply Quote. 3. P1 S1 S1 S1 Lc 4 DTR COM1 5 Signal Ground 6 DSR. Other possible causes are a bad stepper motor or cable. Upon installation, you can see a new Revo directory in the Macros list which contains the following items:. 2. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. 16 and earlier, set the B parameter (beta value) to 4388. 5beta2 regarding the 'M302 P1' cold extrusion command. To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. droftarts administrators @flyscha last edited by . Slic3r 1. @jfavre said in Extruder motor not working. Other possible causes are a bad stepper motor or cable. Business, Economics, and Finance. Heaters, 24v 40W - Im using 24V 400watts power supply. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. Looking for a way that is super native, standalone and low end way to get it to do that without using high level programming architecture, such as not using software that is running on python or what not. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. config. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. g. 0. Already have an account? . There is no minimum steps/mm set in the firmware. Re: Help with extruder feed calibration -. Actual. I tried webcontrol 1. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. The endstop is connected and is working, the wir. If you are using the web interface, go to the Gcode. Retract 150 mm of. 9 ;extrude 0. HI again, what I'm doing wrong, the extruder buttons in DWC won't be gray, its grayed out. However, Slic3r inserts this code after the first Z-lift which is befo. A well-grippable 3d-printable chess set is also included. 5 and 1. g macro is;Autoload filament macro. I would be very gratefull for any help. Compatible with the FlightHub 2 cloud platform and DJI Dock to achieve cloud collaboration and. What am I doing wrong? Thanks in advanceM302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. 3. zip. Send T0 before you try to extrude. Home page Shop all products. $egingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. Heater 1 fault: temperature rising too slowly: expected 2. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0There is one extra complication in moving the extruder. Set the temperature (and enable) using. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. However,. I am setting up a Delta printer with Ramps 1. These are commands that one may enter into the OctoPrint terminal tab. Macros also allow for naming gcodes with easier to remember names. The Matrice 30 series integrates multiple high-performance sensors into a lightweight and portable body. the ONLY command that should spin a motor before the printer homes is G28. extrusion temperature 160. So no need to use M302. The belts are not over tight. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Repetier 1. plan view. Features solid metallic core with. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. droftarts administrators @flyscha last edited by . g. What is the trigger word to tell the firmware that we are starting a new layer? KulitorumHow bout if you heat up the hotend to 180?Hi *, I hope that somebody can help me here. Don't disable the thermal runaway protection. microswitch) endstop. g. Support and Discussion forum for Duet3D Hardware, Firmware, Software, plugins and wider 3d printing/CNC discussion. wordpress. PROMEGA I have installed a BL Touch clone and it works with the direct commands. Other possible causes are a bad stepper motor or cable. Only users with topic management privileges can see it. 9. Edit. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. @dc42 That doesn't seem to work. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . Here is my diagnostic file and my config. g. yello3d. M302 P1 ; allow cold extrusion. 0C. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. I copied the first 2 layer g-code here, and I would like to know if anyone have an idea to solve this issue. Sending T0 initiates the heater and then faults out. 8 amps (JK57HS56-2804) with gear boxes for extra power. I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. Other possible causes are a bad stepper motor or cable. This value gives better accuracy at typical printing temperatures in the range 190 to 250C than the B value of 4267 quoted in the datasheet. So when i home it, x and y go to 225 and z goes to 0. M302. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Set the temperature (and enable) using. 0 S1 ; physical drive 1. 2. Volume 2. 0C, min. 8 is far too low for two reasons: 1. Fan1 configured in thermostatic mode by default. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?M302 P1 ; cold extrude. Here is my diagnostic file and my config. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. Serial No. I have preheated the nozzle to 160 and also tried to issue a M302 P1 but that does not help either. How can I make reprap firmware print without any heater or temperature sensors? Does it have a fake heater that I can make always return 200c or something to make the firmware extrude with a cold extruder, or even wi. Heating Bed manually by G-Code. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. 00°C/sec When you try to heat does the LED near the heater terminal actually turn on? Can. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. 9mm of feed stock. M302 P0. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. If the motor doesn’t turn then check for the Steps/mm setting to see if it got. Only users with topic management privileges can see it. g. I can put a dummy value on the T0 to verify the good functioning of the Titan. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 0C. I probed the STEP output with an oscilloscope and the pulses are there and the pulse length is fine. Other possible causes are a bad stepper motor or cable. I have a setup similar to the ANET A8. Hooray! Again, it's just odd that everything worked with that exact same config in the previous interface. Tools; M563 P1 S"Clay" D0 ; Define tool 1 M563 P2 S"plastic" D1 H2 ; Define tool 2 G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets Some common uses…. So no need to use M302. extrusion temperature 160. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. +Z should move the bed down. Send M302 P1 to allow Cold extrusion Send M600 T1 to initiate Filament swap Follow the Instructions on the Screen. 3 ; Filter. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m),. Ok if the motor is confirmed working, then at least cold extrusion should allow it to extruder as long as the tool is actually selected. @jens55 you are right dude I had missing to remplace one "S" argument by "H" in homez. Users of single-extruder machines often put a T0 command at the end of config. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. 7. 3 ; Filter. 0024. M302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. Re: How can I move E steppers? January 11, 2023 02:36AMI used the safety scissors to cut off the fingers of the severed hand then tried to give her the fingers. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. However, a steps/mm value of 5. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. M302 P1 ; allow cold extrusion. 1) into the DWC console. Sending T0 initiates the heater and then faults out. M302 S160 ; lower cold extrusion limit to 160C {if filament_type[initial_tool]=="FLEX"}G1 E-4 F2400 ; retraction{else}G1 E-2 F2400 ; retraction{endif}. P2 S2 S2 S2 7 RTS Case earth connection. P1: Acute abdominal pain (e. Edit the M305 P1 command in file sys/config. After replacing PCB managed to get everything up and running. Then reduce the distance, and stop just before the filament disappears into the hot end. After you’re done calibrating Esteps, re-enable cold extrusion temperature checking with M302 P0 As has been mentioned, heating the nozzle also works. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. Any help would be greatly appreciated.